企業(yè)新聞 當前位置:首頁-行業(yè)咨詢-企業(yè)新聞羅茨風機驅動電機為什么頻繁被燒毀?

羅茨風機驅動電機為什么頻繁被燒毀?

發(fā)布時間:2022-09-13 來源:http://tgzgw.cn/

一、電機缺相運行
1、 Motor phase failure operation
這是三相異步電機的殺手,電機正常運行時三相負載為對稱負載,因此三相電流基本保持平衡,大小相等,如果運行中電機缺相(三相繞組中任一相斷開的現(xiàn)象叫缺相),風機振動將會變大、出現(xiàn)異常聲音、轉速下降、電流增加,電機溫度將會急劇升高,從而導致電機燒壞,質量一般的電機多十幾分鐘就會燒壞。
This is the killer of three-phase asynchronous motors. During normal operation of motors, the three-phase loads are symmetrical loads, so the three-phase currents are basically balanced and equal. If the motor is short of phase during operation (the phenomenon that any phase of the three-phase windings is disconnected is called phase loss), the fan vibration will increase, abnormal sound will appear, the rotation speed will decrease, the current will increase, and the motor temperature will rise sharply, resulting in the motor burning out, Motors of ordinary quality will burn out in more than ten minutes.
二、軸承損壞
2、 Bearing damage
由于羅茨風機長時間不間斷地運行致使電機本體運行溫升過高,而軸承補充加油脂不及時造成軸承缺油直軸承損壞、會出現(xiàn)軸彎曲、皮帶斷裂等現(xiàn)象,致使定、轉子摩擦(俗稱掃膛)引起鐵心溫度急劇上升,燒毀槽絕緣、匝間絕緣,從面造成繞組匝間短路或對地“放炮”。嚴重時會使定子鐵心倒槽、錯位、轉軸磨損、端蓋報廢等。
Due to the continuous operation of Roots blower for a long time, the operating temperature rise of the motor body is too high, and the failure to add grease to the bearing in time causes the bearing to be short of oil until the bearing is damaged, the shaft will be bent, the belt will be broken, and so on. As a result, the friction between the stator and rotor (commonly known as bore sweeping) will cause the core temperature to rise sharply, burn the slot insulation and turn to turn insulation, and cause the winding turn to turn short circuit or "blasting" to the ground from the surface. In serious cases, the stator core will be inverted, misaligned, the rotating shaft will be worn, and the end cover will be scrapped.
正和羅茨風機車間
Zhenghe roots blower workshop
三、風閥關閉的情況下會造成過載燒毀
3、 When the air valve is closed, it will cause overload and burn
由于羅茨風機啟動后風閥未有打開或打開的量不夠。而風機在此情況運行下,致使由于羅茨風機電機本體運行溫度急劇上升直燒毀風口或風閥復位后,而風機未及時關閉,而風機在此情況運行下,也會致使由于電機本體運行溫度急劇上升直燒毀。如果是保護功能正常(加裝合適的熱繼電器),一般不會發(fā)生。但是,要注意的是,因熱繼電器無法校驗,并且保護數(shù)值也不十分準確,選型不合適等等加上人為設置成自動復位,所以需要保護的時候,往往起不到作用,也可能多次保護以后,沒有找到原因,人為調高保護數(shù)值。使保護失效。
Because the air valve is not opened or the opening amount is not enough after the roots blower is started. When the fan operates under this condition, the operating temperature of the motor body of Roots blower rises sharply until the tuyere is burned or the air valve is reset, but the fan is not closed in time. When the fan operates under this condition, the operating temperature of the motor body rises sharply until it is burned. If the protection function is normal (add a suitable thermal relay), it will not happen generally. However, it should be noted that because the thermal relay can not be calibrated, and the protection value is not very accurate, the selection is not appropriate, etc., and the manual setting is automatic reset, it often does not work when protection is needed. It may also be that after several times of protection, the reason is not found, and the protection value is manually increased. To disable the protection.
四、受潮
4、 Damp
因為配電柜或電機進水或受潮造成的絕緣降低,也是常見的損壞原因,但是沒有辦法作防護。只能使用中注意和定期搖絕緣。在電機沒爆以前,烘干、重新浸漆可解決。尤其是用變頻器驅動的電機,更要小心此項,不然可能連變頻器一塊報銷。
Insulation degradation caused by water ingress or moisture in the distribution cabinet or motor is also a common cause of damage, but there is no way to protect it. Only pay attention to and shake the insulation regularly during use. Before the motor explodes, it can be solved by drying and re dipping. Especially for the motor driven by the frequency converter, be more careful about this item, otherwise it may be reimbursed together with the frequency converter.
五、其它
5、 Other
另外還有的不是很常見的原因:如電壓過低或過高,震動造成接線柱松脫相間短路,蟲鼠危害、進口電機電壓與國內電壓不配合。各種減壓起動回路故障造成不轉換,羅茨風機電機長時間低壓工作等。因此,在使用前注意預先檢查各項指標后在啟動,可以減小事故率。
In addition, there are other reasons that are not very common: for example, the voltage is too low or too high, the terminal is loose and the phase to phase short circuit is caused by vibration, insects and rats are harmful, and the voltage of imported motor does not match the domestic voltage. Failure of various reduced pressure starting circuits results in non switching and long-term low-voltage operation of Roots blower motor. Therefore, the accident rate can be reduced by paying attention to checking all indicators in advance before use and starting.
以上就是為大家介紹的有關山東羅茨風機的詳細的介紹,希望對您有所幫助.如果您有什么疑問的話,歡迎聯(lián)系我們.我們將以的態(tài)度,為您提供服務http://tgzgw.cn/
The above is the detailed introduction about Shandong roots blower. I hope it can help you. If you have any questions, please contact us. We will provide you with services in a professional manner http://tgzgw.cn/